Lecture 12: OoO 1
Section 1: Complex Pipelines, Hazard Taxonomy, and In-Order Limitations
Now we shift our focus inside the processor core. Simple 5-stage pipelines assume every arithmetic operation completes in 1 cycle and memory takes 1 cycle. Pipelining becomes complex when we want high performance in the presence of:
- Long-latency or partially pipelined floating-point units (FPUs), such as an unpipelined divider (
FDiv), multi-cycleFAddandFMul. - Memory systems with variable access time (cache hits vs. cache misses).
- Multiple arithmetic and memory units operating in parallel.
To talk cleanly about these machines, let’s establish four precise pipeline boundaries across the Frontend (instruction fetch/decode) and Backend (execution, "EXE stage"):
- Dispatch: Instructions are dispatched when they leave decode and enter the instruction pool.
- Issue: Instructions are issued when they exit the instruction pool to a functional unit.
- Complete: Instructions are completed when they finish execution and produce their result/exception flags at Writeback.
- Commit: (We will separate this from completion shortly) when an instruction updates permanent architectural state.
Why Simple In-Order Complex Pipelines Struggle
Suppose we attach multiple functional units (ALU, Mem, FAdd, FMul, FDiv) to an Issue stage with general-purpose (GPRs) and floating-point (FPRs) register files. Four hazards immediately appear:
- Structural hazards on iterative functional units (e.g., issuing a second divide while the unpipelined
FDivis busy). - Structural hazards on writeback (two instructions of different latencies finishing on the same cycle and fighting for one
WBport). - WAR and WAW data hazards (explained below).
- Exception handling (a fast instruction finishing after an older slow instruction that later traps).
In an in-order complex pipeline, we can simplify control by padding shorter pipelines to equalize EXE cycle latency (putting X1, X2, X3 stages on everything) and enforcing an in-order Commit Point right before W. That eliminates WB structural hazards, WAR/WAW hazards, and imprecise exceptions. To prevent the padded writeback latency from slowing down single-cycle integer operations, we add massive bypassing networks—but bypassing becomes extremely expensive with multiple padded functional units.
Can we remove the padding and let functional units run at their natural, unequal latencies without massive bypassing? If we do, we must check four conditions before issuing any instruction from a tracking table:
- Is the required functional unit available? (Structural)
- Is the input data available? (RAW hazard?)
- Is it safe to write the destination? (WAR? WAW hazard?)
- Is there a structural conflict at the
WBstage?
Review: Data Hazard Taxonomy (Register vs. Memory)
Consider executing a sequence of instructions of the form r_k \leftarrow r_i \text{ op } r_j:
- Data-dependence — Read-after-Write (RAW) hazard (a true dependence): r_3 \leftarrow r_1 \text{ op } r_2 r_5 \leftarrow r_3 \text{ op } r_4 The second instruction needs the value produced by the first.
- Anti-dependence — Write-after-Read (WAR) hazard (a name dependence): r_3 \leftarrow r_1 \text{ op } r_2 r_1 \leftarrow r_4 \text{ op } r_5 The second instruction overwrites r_1; if it writes before the first reads r_1, the first reads the wrong value.
- Output-dependence — Write-after-Write (WAW) hazard (a name dependence): r_3 \leftarrow r_1 \text{ op } r_2 r_3 \leftarrow r_6 \text{ op } r_7 Both write r_3; if the second finishes before the first, r_3 ends up with the older value instead of the newer one.
Notice a crucial difference between register and memory operands: data hazards due to register operands can be determined at the decode stage (just by comparing register numbers), but data hazards due to memory operands (M[r1 + disp1] <- r2 followed by r3 <- M[r4 + disp2]) can be determined only after computing the effective address—specifically, checking whether (r_1 + \text{disp}_1) = (r_4 + \text{disp}_2). (We will tackle memory hazards in Lecture 13.)
Worked Example: Dependency Graph and Out-of-Order Completion
Let’s trace all hazards in the following 6-instruction floating-point sequence:
- I_1:
FDIV.D f6, f6, f4(latency 4) - I_2:
FLD f2, 45(x3)(latency 1) - I_3:
FMUL.D f0, f2, f4(latency 3) - I_4:
FDIV.D f8, f6, f2(latency 4) - I_5:
FSUB.D f10, f0, f6(latency 1) - I_6:
FADD.D f6, f8, f2(latency 1)
Let’s map every hazard:
- RAW hazards: I_1 \to I_4 (
f6), I_1 \to I_5 (f6), I_2 \to I_3 (f2), I_2 \to I_4 (f2), I_2 \to I_6 (f2), I_3 \to I_5 (f0), I_4 \to I_6 (f8). - WAR hazards: I_4 \to I_6 (
f6is read by I_4 and written by I_6), I_5 \to I_6 (f6is read by I_5 and written by I_6). - WAW hazards: I_1 \to I_6 (both write
f6).
From this dependency graph, valid instruction orderings include in-order (I_1, I_2, I_3, I_4, I_5, I_6), or out-of-order schedules such as I_2, I_1, I_3, I_4, I_5, I_6 (swapping independent I_1, I_2) or I_1, I_2, I_3, I_5, I_4, I_6 (moving I_5 ahead of I_4 because I_5 doesn’t depend on I_4).
Now let’s keep in-order issue (instructions issue one per cycle in program order) and compare in-order completion against out-of-order completion cycle-by-cycle (writing k for the cycle I_k issues, and \underline{k} for the cycle I_k completes):
- In-Order Issue, In-Order Completion:
- Cycle 1:
1(I_1 issues, takes 4 cycles \to ready Cycle 5) - Cycle 2:
2(I_2 issues, takes 1 cycle \to ready Cycle 3, must wait to complete after I_1) - Cycles 3–4: stall (I_3 needs
f2from I_2, which hasn’t completed) - Cycle 5: \underline{1} (I_1 completes)
- Cycle 6: \underline{2} (I_2 completes)
- Cycle 7:
3(I_3 issues, takes 3 cycles \to ready Cycle 10) - Cycle 8:
4(I_4 issues;f6andf2are ready! Takes 4 cycles \to ready Cycle 12) - Cycle 9: stall (I_5 needs
f0from I_3) - Cycle 10: \underline{3} (I_3 completes)
- Cycle 11:
5(I_5 issues, takes 1 cycle \to ready Cycle 12, must wait for I_4) - Cycle 12: \underline{4} (I_4 completes)
- Cycle 13:
6(I_6 issues, takes 1 cycle \to ready Cycle 14) - Cycle 14: \underline{5} (I_5 completes)
- Cycle 15: \underline{6} (I_6 completes) — 15 cycles total.
- Cycle 1:
- In-Order Issue, Out-of-Order Completion:
- Cycle 1:
1 - Cycle 2:
2 - Cycle 3: \underline{2} (I_2 completes immediately out of order!)
- Cycle 4:
3(I_3 issues \to ready Cycle 7) - Cycle 5: \underline{1} (I_1 completes)
- Cycle 6:
4(I_4 issues \to ready Cycle 10) - Cycle 7: \underline{3} (I_3 completes)
- Cycle 8:
5(I_5 issues \to ready Cycle 9) - Cycle 9: \underline{5} (I_5 completes ahead of I_4!)
- Cycle 10: \underline{4} (I_4 completes)
- Cycle 11:
6(I_6 issues) - Cycle 12: \underline{6} (I_6 completes) — 12 cycles total.
- Cycle 1:
Where In-Order Issue Still Fails
Out-of-order completion helped above, but look what happens with a slightly different sequence when FLD misses in the cache (latency = long, say 7 cycles):
- 1:
FLD f2, 34(x2)(latency 1) - 2:
FLD f4, 45(x3)(latencylong) - 3:
FMULT.D f6, f4, f2(latency 3, RAW on 1, 2) - 4:
FSUB.D f8, f2, f2(latency 1, RAW on 1) - 5:
FDIV.D f4, f2, f8(latency 4, RAW on 1, 4; WAR on 3 (f4)) - 6:
FADD.D f10, f6, f4(latency 1, RAW on 3, 5)
Under in-order issue: 1 2,1_ . . . . . . 2_ 3 4 4_ 3_ 5 . . . 5_ 6 6_ (20 cycles). Notice that on Cycle 3, instruction 4 (FSUB.D f8, f2, f2) already has its operand f2 ready! Yet the in-order issue restriction prevents instruction 4 from being issued simply because instruction 3 ahead of it is stuck waiting on the long load (2). To hide long-latency operations, we must allow independent younger instructions to issue out of order.
[Editor Note: removed title slide, previous-lecture recap slide, and roadmap slide.]
✎ Check Your Understanding
What are the three types of data hazards, and which one represents a true dependency as opposed to a name dependency? Answer: RAW (Read-after-Write, true data-dependence), WAR (Write-after-Read, anti-dependence), and WAW (Write-after-Write, output-dependence). Only RAW is a true dependency; WAR and WAW are name dependencies.
In the second 6-instruction trace above, why did instruction 4 (
FSUB.D f8, f2, f2) sit idle for 8 cycles under in-order issue even thoughf2became available on Cycle 2? Answer: Because instruction 3 (FMULT.D) was stalled waiting on the long-latency load (2), and in-order issue forbids issuing instruction 4 before all preceding instructions have issued.
Section 2: Out-of-Order Issue and Why Register Renaming Is Essential
To break the bottleneck of in-order issue, we place an Instruction Pool between Dispatch and Issue:
- The pool holds multiple instructions waiting to issue.
- Dispatch adds the next instruction in program order to the pool if there is space and the instruction does not cause a WAR or WAW hazard. (Note: WAR becomes possible again! Under in-order issue, if an instruction registered its input operands at its functional unit upon issue, no younger instruction could write before the older instruction read. With out-of-order issue, a younger instruction in the pool could issue and overwrite a register before an older waiting instruction reads it!)
- Issue selects any instruction in the pool whose RAW hazards are satisfied (for now, at most one issue per cycle). On writeback (
WB), waiting instructions are enabled.
Let’s apply naive Out-of-Order Issue (without renaming) to our exact 6-instruction example with the long load (2):
- Cycle 1:
1(I_1 issues) - Cycle 2:
2, \underline{1} (I_2 issues; I_1 completes) - Cycle 3:
4(I_4 issues out of order ahead of I_3!) - Cycle 4: \underline{4} (I_4 completes!)
- Cycles 5–8:
. . . .— Stuck! Why can’t instruction 5 (FDIV.D f4, f2, f8) issue even thoughf2andf8are both ready? Because instruction 3 (FMULT.D f6, f4, f2) has not readf4yet, creating a WAR hazard onf4! - Cycle 9: \underline{2} (I_2 completes)
- Cycle 10:
3(I_3 issues) - Cycle 13: \underline{3} (I_3 completes)
- Cycle 14:
5(I_5 issues) - Cycle 18: \underline{5} (I_5 completes)
- Cycle 19:
6(I_6 issues) - Cycle 20: \underline{6} (I_6 completes).
Look at that result: Out-of-order execution did not allow any significant improvement! It still took 20 cycles!
And this is not a contrived example—it is typical in loops. Consider:
while (...) {
A[i] += x;
}Compiled into assembly:
L1: FLD f4, 0(x3)
ADDD f6, f4, f2
FST 0(x3), f6
ADD x3, x3, 8
j L1
Every single iteration reuses architectural registers f4 and f6. Even if the first FLD misses in cache, the second iteration cannot start its FLD into f4 because of WAR/WAW hazards on f4 and f6! Thus, the number of registers in an ISA limits the number of instructions that can be in the pipeline, and out-of-order issue by itself does not provide any significant performance improvement!
Register Renaming to the Rescue
Floating-point pipelines often cannot be kept filled with a small number of architectural registers (for instance, the IBM 360 had only 4 floating-point registers). Can a microarchitecture use more registers than specified by the ISA without breaking ISA compatibility?
Yes! Robert Tomasulo of IBM suggested an ingenious solution in 1967 using on-the-fly register renaming. Any anti-dependence (WAR) or output-dependence (WAW) can be eliminated by giving the new write a fresh storage location (name). Look at what happens to our 6-instruction example when hardware renames f4 in instructions 5 and 6 to a fresh internal register f4':
- 3:
FMULT.D f6, f4, f2 - 5:
FDIV.D f4', f2, f8 - 6:
FADD.D f10, f6, f4'
The WAR edge between 3 and 5 disappears! Now watch the execution schedule:
- Cycle 1:
1 - Cycle 2:
2, \underline{1} - Cycle 3:
4 - Cycle 4: \underline{4}
- Cycle 5:
5(I_5 issues right away, overlapping its 4-cycle divide with the long load I_2!) - Cycle 9: \underline{2} (I_2 completes)
- Cycle 10:
3, \underline{5} (I_3 issues and I_5 finishes!) - Cycle 11: \underline{3} (I_3 completes; compressed in diagram notation)
- Cycle 12:
6(I_6 issues) - Cycle 13: \underline{6} (I_6 completes) — down from 20 cycles to ~13 cycles!
In the pipeline, Decode performs register renaming and adds instructions to the issue-stage Reorder Buffer (ROB) (our instruction pool). Because every write gets a unique renamed destination, renaming makes WAR and WAW hazards impossible. Any instruction in the ROB whose RAW hazards are satisfied can be issued immediately, yielding true out-of-order (dataflow) execution.
✎ Check Your Understanding
Why did naive out-of-order issue fail to speed up the 6-instruction sequence when
FLD f4had a long latency? Answer: Instruction 5 (FDIV.D f4, f2, f8) had a WAR hazard onf4with the stalled instruction 3 (FMULT.D f6, f4, f2), blocking 5 and 6 from executing ahead of 3.Which two hazard types are completely eliminated by register renaming, and which one remains? Answer: WAR and WAW hazards are completely eliminated; only RAW hazards (true data dependences) remain.
Section 3: Data-in-ROB Microarchitecture and Separating Completion from Commit
How do we build register renaming and out-of-order execution in hardware? Let’s examine the “Data-in-ROB” design first.
Renaming Structures (Data-in-ROB)
There are two central tables:
- Renaming Table & Architectural Register File (Regfile): One entry per architectural register (
f1,f2, …), containing a presence bitpand adata / tagfield:- If
p = 1(present), the architectural register holds the valid, up-to-date data value. - If
p = 0(busy), the field holds a tag (t_i) pointing to the ROB slot of the instruction that will produce that register’s value.
- If
- Reorder Buffer (ROB): A FIFO queue of instruction templates with slots indexed by tags t_1, t_2, \dots, t_n (
Head= oldest,Tail= newest). Each ROB entry tracks:i(issued bit),Opcode(op)- Source 1:
p1(presence bit),Tag / Src1(either the ready value ifp1=1, or producer tag t_k ifp1=0) - Source 2:
p2,Tag / Src2 - Destination:
p_dst(whether result is ready),Reg(architectural destination register),Result(holds completed value before commit), andExcept?(exception flags).
Let’s trace the four lifecycle events of an instruction in this machine:
- Dispatch (at Decode, in program order):
- Allocate the next ROB slot at
Tail(its index t is this instruction’s tag). - Read source operands from the architectural regfile/rename table. If an operand is non-busy (
p=1), copy its value toSrc1/Src2withp=1. If it is busy (p=0), read<p, result>from the producing ROB slot at that tag index (bypassing if just completed); if still not ready, copy the producer’s tag t_k intoSrcand setp=0. - Write the destination architectural register entry in the rename table with
<p=0, Tail, _>so all future readers point to this instruction’s tag.
- Allocate the next ROB slot at
- Issue (out of order):
- Whenever an entry has
i=0and bothp1=1andp2=1(and its FU is free), seti=1and dispatch the operation and values to the Functional Unit.
- Whenever an entry has
- Completion (out of order):
- The FU broadcasts
<t, result>onto a common bus. - The ROB writes
ResultandExcept?into slottand setsp_dst = 1. - Simultaneously, all waiting
Src1andSrc2fields in the ROB are searched associatively for tagt; on a match, the hardware setsp=1and copiesresultintoSrc. (Note: replacing the tag by its value via associative CAM broadcast across every ROB source slot is an expensive hardware operation!)
- The FU broadcasts
- Commit (in order, at
Head):- Wait until the oldest instruction at
Headhasp_dst = 1. - Check
Except?. If no trap, copyResultinto the architectural register file: if the rename table’s tag forRegstill matchesHead(no younger writer overwrote the mapping), set<1, _, Result>; otherwise (a younger instruction already renamedReg), update the committed value while leaving the rename table’s busy tag intact (<0, _, Result>). Then dequeueHead. - When can a tag/name be reused? Only whenever an instruction commits (freeing its ROB slot).
- Wait until the oldest instruction at
Why Separate Completion from Commit?
In early out-of-order machines (like Tomasulo’s original IBM 360/91), completion equaled commit: as soon as an instruction finished executing, it immediately updated architectural registers. That creates two severe problems:
- WAW hazards if a younger instruction writes before an older one if not carefully gated.
- Imprecise traps/exceptions: If instruction I_4 finishes and overwrites
f8before older instruction I_1 finishes and discovers a divide-by-zero or page fault, the architectural state is already corrupted when the trap fires! Imprecise traps make debugging and OS virtual-memory restarts nearly impossible.
By separating completion from commit, the ROB holds completed values temporarily (out-of-order completion) and updates architectural state strictly in program order (in-order commit). Look at how a snapshot of the ROB moves from Cycle t to Cycle t + 1:
- At
Cycle t, the ROB holds active decoded-but-uncommitted instructions from oldest (ld x1, (x3)atHead) down toadd x6, x6, x3. Younger instructions (sd x6, (x1),ld x6, (x1)) are still being fetched. - At
Cycle t + 1,ld x1, (x3)commits (leaving the ROB), the middle instructions continue to execute (and dependents can bypass completed values straight out of the ROB before commit), and the newer instructions are fetched and enter the bottom of the ROB.
When a Trap is detected at the Commit point:
- Hardware kills all younger instructions in the ROB, Decode, and Fetch, resets the Rename Table (
All p=1), setsfree = oldest, and injects the trap handler PC into Fetch. Because no younger instruction has touched architectural state yet, the trap is 100% precise.
What if we need to flush only part of the ROB without taking a full trap—such as on a branch misprediction? Repairing the rename table on a partial squash is non-trivial because every enqueued instruction after the branch modified the rename table. Two solutions exist:
- Rename unwind: Walk backward from the tail of the ROB to the branch, restoring old mappings.
- Rename table snapshots: Save a copy of the rename table per branch (or per instruction) so it can be restored in a single cycle on misprediction.
Historical Perspective: Why OoO Faded Until the 1990s
Tomasulo’s 1967 IBM 360/91 FPU pioneered distributed reservation stations (3 entries for the Adder, 2 for the Multiplier, 6 load buffers, 3 store buffers) connected by a Common Data Bus (<tag, result>) that broadcast results to all waiting entries simultaneously. Yet despite being built commercially in the 1960s, out-of-order execution largely disappeared until the 1990s for two architectural and two economic reasons:
- Two missing architectural pieces: Precise traps (without a ROB, early OoO machines had imprecise traps) and branch prediction (without accurate speculation, control hazards starved the instruction window of ILP).
- Technology scaling: Simpler in-order designs in newer semiconductor technology beat complicated multi-board OoO machines in older technology—fitting the processor and caches onto a single chip gave microprocessors an era of ~1%/week performance scaling before OoO became necessary again.
[Editor Note: removed blank transition slide and acknowledgements slide.]
✎ Check Your Understanding
In a Data-in-ROB machine, when are source tags replaced by actual data values, and when can an instruction’s ROB tag/slot be reused? Answer: Source tags are replaced by data whenever a functional unit produces data (via associative broadcast on completion). A ROB tag/slot can only be reused whenever that instruction commits in order at the ROB head.
Why did separating completion from commit solve the problem of imprecise traps? Answer: Out-of-order completion writes results and exception flags only into temporary ROB buffers; architectural state is updated strictly in program order at commit, so if an older instruction traps, all younger instructions can be cleanly killed before they alter architectural state.