Lecture 17: VLIW

Section 1: Superscalar Scaling Limits and the VLIW Philosophy

We have built a remarkably capable machine: virtual memory with hardware TLBs, register renaming, out-of-order issue, speculative load-store disambiguation, and tournament/trace-cache branch speculation. Now step back and ask a brutal hardware engineering question: How does this out-of-order control logic scale as we make the processor wider?

Suppose our processor has Issue Width W (issuing W instructions per cycle) and each instruction has an active Lifetime L cycles in the machine:

Look at the die photo of the MIPS R10000 (1995): a huge portion of the silicon area (IF inst, IF addr, Free List, Grad Unit, Address Queue, Integer Queue, FP Queue, Register Rename) is pure Control Logic dedicated to figuring out what can run in parallel—not caches (Instruction Cache, Data Cache) and not actual compute (Integer Datapath, FP Datapath, FP Mult)!

And look at the absurdity of the Sequential ISA Bottleneck:

  1. The programmer writes sequential source code (a = foo(b); for (i=0; ...)).
  2. The superscalar compiler analyzes the code, builds a dependency graph, finds independent operations, and schedules them—only to flatten them back into a sequential machine code stream!
  3. At runtime, the superscalar processor must burn huge hardware power and \sim W^3 area to re-check instruction dependencies and reconstruct the exact parallel schedule the compiler already knew!

The VLIW (Very Long Instruction Word) Solution

Why not let the compiler tell the hardware explicitly which operations execute in parallel? That is VLIW—also called SPIE (Static Parallel Instruction Execution) by pioneer Joseph A. Fisher (who also coined “memory disambiguation” for the unknown memory address problem).

In a VLIW architecture:

All of that \sim W^3 issue queues, CAM wakeup logic, and register renaming disappears, replaced by the VLIW compiler, which must:

  1. Schedule operations to maximize parallel execution.
  2. Guarantee intra-instruction parallelism.
  3. Schedule around known latencies to avoid data hazards—typically inserting explicit NOPs wherever data isn’t ready yet.

Historical milestones showed how wide VLIWs could go: the FPS AP120B (1976) was the first commercial wide-instruction array processor (relying on hand-coded software pipelining and loop unrolling); the Multiflow Trace (1987) packed up to 28 operations into a 1024-bit instruction word using trace scheduling; and the Cydrome Cydra-5 (1987) encoded 7 operations into a 256-bit word with a rotating register file.

[Editor Note: removed title slide, previous-lecture recap slide, and Fisher’s personal naming/grant-proposal anecdote.]

✎ Check Your Understanding

  1. Why does out-of-order superscalar control logic grow faster than W^2 (closer to \sim W^3) as issue width W increases? Answer: Each of the W issued instructions must check against W \times L in-flight instructions (\propto W^2 L), and wider machines require deeper instruction windows to uncover enough ILP, causing lifetime L to grow alongside W.

  2. What two architectural guarantees must a VLIW compiler satisfy so hardware can eliminate dependency-checking and interlock logic? Answer: All operations packed into the same VLIW instruction must be mutually independent (no cross-op RAW hazards), and no instruction may read an operand before its producer’s fixed architectural latency has elapsed.


Section 2: Static Loop Scheduling — Loop Unrolling, Software Pipelining, and Trace Scheduling

Since a VLIW processor has no dynamic hardware scheduler, all performance comes from the compiler’s static scheduling. Let’s trace a concrete loop step-by-step on our 6-slot VLIW machine (Int1, Int2, M1, M2, FP+, FPx), assuming Int = 1 cycle, Mem (fld/fsd) = 3 cycles, and FP (fadd) = 4 cycles.

Consider:

for (i = 0; i < N; i++)
    B[i] = A[i] + C;

Compiled into scalar-style assembly (f0 holds C, x1 points to A, x2 points to B, x3 is the loop bound):

loop: fld  f1, 0(x1)
      add  x1, 8
      fadd f2, f0, f1
      fsd  f2, 0(x2)
      add  x2, 8
      bne  x1, x3, loop

Attempt 1: Naive VLIW Scheduling

Look at what happens when we schedule one iteration directly onto the 6-slot VLIW grid:

Throughput: 1 fadd / 8 cycles = 0.125 FLOPS/cycle! Out of 8 \times 6 = 48 available operation slots, we used only 6!

Attempt 2: Loop Unrolling (4 Ways)

To fill those empty latency cycles, the compiler unrolls the inner loop to perform 4 iterations at once (i += 4, handling non-multiples of 4 with a small cleanup loop):

Throughput jumps to 4 fadds / 11 cycles = 0.36 FLOPS/cycle. Better—but notice why we are still wasting 7 of the 11 cycles on FP+: we wait for all 4 loads and adds to finish before starting the next batch of 4 loads!

Attempt 3: Software Pipelining

Why wait to finish iteration k’s stores before starting iteration k+1’s loads? Software pipelining overlaps operations from different loop iterations so the M1, M2, and FP+ units stay busy simultaneously!

Look at our 4-way unrolled loop after software pipelining:

Look at the steady-state throughput: 4 fadds / 4 cycles = 1.0 FLOPS/cycle—an 8\times speedup over naive scheduling, keeping FP+ 100% utilized!

Let’s see how a compiler writes a basic software-pipelined loop for the simpler 1-per-iteration case (fld f0, 0(x1) \to fadd f4, f0, f2 \to fsd f4, 0(x1) \to addi x1, x1, -8 \to bne):

Compare Software Pipelining vs. Loop Unrolling: Loop unrolling pays startup and wind-down ramp overhead on every unrolled iteration (sawtooth utilization), whereas software pipelining pays startup/wind-down costs only once per loop, keeping execution flat at peak throughput!

What If There Are No Loops? Trace Scheduling

Real programs aren’t just dense numerical loops; control-flow-intensive irregular code has frequent branches that shrink each basic block to only a handful of instructions, leaving little ILP inside any single block.

To extract parallelism across branches in VLIW, Trace Scheduling (Fisher & Ellis) uses profiling feedback or compiler heuristics to pick a string of basic blocks—a trace—representing the most frequent branch path through the control-flow graph. The compiler treats the entire trace as one giant basic block and schedules all of its operations in parallel at once! Whenever an operation moves above or below a side branch, the compiler generates extra fixup (compensation) code along the off-trace branch paths to preserve correctness if execution ever leaves the trace.

✎ Check Your Understanding

  1. In the steady-state software-pipelined Loop' above (fsd f4, 16(x1), fadd f4, f0, f2, fld f0, 0(x1)), why does fsd appear before fadd and fadd before fld? Answer: Because fsd must read the previous iteration’s sum in f4 before fadd overwrites f4, and fadd must read the previous iteration’s loaded value in f0 before fld overwrites f0—each instruction belongs to a different logical loop iteration (i, i+1, i+2).

  2. Why does Trace Scheduling require “fixup code” on branches that exit the trace? Answer: Because scheduling the trace as one block moves instructions across branch boundaries; if runtime execution takes an off-trace branch, fixup code must execute any skipped operations or undo speculative side effects.


Section 3: Classic VLIW Pitfalls, EPIC (IA-64), Rotating Registers, and Speculation

Despite its hardware simplicity, “Classic” VLIW suffered five major practical problems:

  1. Object-code compatibility: Because hardware latencies and functional unit counts are baked into the instruction encoding, you must recompile all code for every new machine, even two models in the same processor generation!
  2. Object code size: Empty NOP slots waste instruction memory and I-cache capacity, while loop unrolling and software pipelining replicate code. (Three encoding schemes tried to reduce unused fields: storing a compressed format in memory and expanding on I-cache refill as in the Multiflow Trace—which complicates branch target addressing; marking explicit parallel groups as in TI TMS320C6x DSPs and Intel IA-64; or providing a single-op VLIW instruction like Cydra-5 UniOp.)
  3. Variable-latency memory operations: Caches and memory bank conflicts introduce latency variability that the compiler cannot predict statically.
  4. Knowing branch probabilities: Trace scheduling requires profiling runs as a heavy extra step in the software build process.
  5. Statically unpredictable branches: The optimal schedule changes depending on which branch path is taken at runtime.

Intel Itanium and EPIC (IA-64)

To bring VLIW into mainstream enterprise computing while fixing object-code compatibility, Intel and HP introduced EPIC (Explicitly Parallel Instruction Computing—essentially VLIW) with the IA-64 ISA (implemented in Merced, McKinley, and up to the 8-core, 2-way multithreaded Poulson fetching two 128-bit bundles / 6 instructions per cycle and executing up to 12 instructions/cycle).

How did IA-64 achieve object-code compatibility? Instead of locking operations to fixed machine slots, IA-64 packs three 41-bit instructions plus a 5-bit Template into a 128-bit instruction bundle: [\ \text{Instruction 2}\ |\ \text{Instruction 1}\ |\ \text{Instruction 0}\ |\ \text{Template}\ ] The Template bits encode stop bits marking groups of mutually independent instructions (which can span across bundle boundaries, e.g., group i spanning bundle j-1, bundle j, and bundle j+1). A narrower machine executes a large group over multiple cycles, while a wider machine executes it in one cycle—preserving binary compatibility! IA-64 also provided massive register state: 128 64-bit GPRs, 128 64/80-bit FPRs, and 64 1-bit Predicate Registers.

Three Hardware Features to Help the Compiler

To overcome VLIW’s loop-size, branch, and memory-latency barriers, Cydra-5 and IA-64 introduced three clever architectural features:

  1. Rotating Register Files (for Software Pipelining): Scheduled software-pipelined loops consume lots of registers and duplicate prolog/epilog code. Solution: Add a Rotating Register Base (RRB) register that points to the base of the current iteration’s register set: \text{Physical Register} = \text{Logical Register Specifier} + \text{RRB} On each loop branch (bloop), RRB decrements by 1, automatically allocating a fresh set of physical registers for the new iteration without duplicating code! (Usually the register file is split into rotating and non-rotating registers.)

    Worked Example: Suppose a loop has a 3-cycle load and a 4-cycle fadd. Look at how the compiler encodes latencies directly in the register specifier differences: \texttt{ld f1, ()} \quad|\quad \texttt{fadd f5, f4, ...} \quad|\quad \texttt{sd f9, ()} \quad|\quad \texttt{bloop} Notice f4 - f1 = 3 (load latency) and f9 - f5 = 4 (fadd latency)! Let’s trace RRB counting down from 8 to 1:

    • Iteration at RRB = 8: ld writes P(1+8) = P9. (fadd reads P12, writes P13; sd reads P17.)
    • Three iterations later (RRB = 5): ld writes P6, and fadd reads P(4+5) = P9—receiving the exact value ld started loading 3 cycles earlier! Meanwhile, fadd writes P(5+5) = P10.
    • Four iterations later (RRB = 1): sd reads P(9+1) = P10—storing the exact sum fadd started computing 4 cycles earlier!
  2. Predicated Execution (for Hard-to-Predict Branches): To eliminate mispredicted branches, almost every IA-64 instruction can execute conditionally under a 1-bit predicate register (becoming a NOP if its predicate is false). An if-then-else diamond spanning four basic blocks (b0: br a==b, b2, b1: else, b2: then, b3: join) collapses into one basic block:

    Inst 1
    Inst 2
    p1, p2 <- cmp(a == b)
    (p1) Inst 3  ||  (p2) Inst 5
    (p1) Inst 4  ||  (p2) Inst 6
    Inst 7
    Inst 8

    Predication removes >50\% of branches on average (Mahlke et al.), Warning: it complicates bypassing! (If Inst 3 and Inst 5 both target the same register under mutually exclusive predicates, hardware must check predicates before bypassing.)

  3. Control Speculation (Load.s / Chk.s) and Data Speculation (Load.a / Load.c):

    • Control Speculation: Moving a Load r1 above a branch (br a==b, b2) is illegal normally because if the branch isn’t taken, Load r1 might dereference a null pointer and cause a spurious page fault! IA-64 solves this by hoisting a speculative load (Load.s r1) above the branch: Load.s never raises an exception, instead setting a “poison” bit (NaT) on destination register r1. In the load’s original home block, Chk.s r1 checks whether the poison bit is set and jumps to fixup code only if the branch actually took that path.
    • Data Speculation: Moving Load r1 above an earlier Store is illegal if their pointers might alias. IA-64 hoists an advanced load (Load.a r1) above the Store, recording its address in an associative address check table. Any intervening Store checks the table and invalidates matching addresses. In the original location, Load.c checks whether r1’s entry is still valid (and not evicted); if invalidated or missing, it jumps to fixup code to reload. (Note: this requires associative CAM hardware in the address check table—creeping right back toward superscalar complexity!)

Limits of Static Scheduling

Ultimately, despite massive engineering effort, VLIW failed in general-purpose computing—as Donald Knuth famously observed of Itanium, “the wished-for compilers were basically impossible to write,” and Intel formally discontinued Itanium in 2019. Statically unpredictable branches, variable cache-miss latencies, code size explosion, and compiler complexity meant complex VLIW machines approached in-order superscalars in hardware complexity with no advantage on large, irregular applications. However, VLIW has been highly successful in the embedded DSP market, where simpler VLIWs run in constrained environments with predictable loops and deterministic memory!

[Editor Note: removed title slide and acknowledgements slide.]

✎ Check Your Understanding

  1. In a Rotating Register File, suppose a mul has a 5-cycle latency and the loop executes mul f2, ... followed by add ..., f7, ... with RRB decrementing by 1 each cycle. If RRB = 10 when mul executes, what physical register does mul write, and what will RRB be when add reads that exact physical register? Answer: At RRB = 10, mul writes P(2 + 10) = P12. Five cycles later, RRB = 5, and add reads P(7 + 5) = P12.

  2. Why does IA-64’s Load.s set a “poison” bit instead of immediately raising a page fault or segmentation fault? Answer: Because Load.s was hoisted speculatively above a branch; if that branch turns out not to enter the load’s original block, the exception would have been spurious. Deferring the check to Chk.s in the home block ensures exceptions trigger only when truly needed.